• Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
  • Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
  • Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
  • Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
  • Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
  • Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement

Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement

After-sales Service: Yes
Warranty: 12months
Cooling Method: Evaporative Condenser
Ventilation Mode: Mechanical Ventilation
Material: PVC
Air Contact Form: Wet
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Hebei, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
Full Customization
The supplier provides full customization services
Private Mold
The supplier has private mold
to see all verified strength labels (18)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Packaging & Shipping
  • Installation Instructions
  • Related products
  • Company Profile
Overview

Basic Info.

Model NO.
ST-L085
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ordinary
Application Fields
Industrial
Certification
ISO, SGS
Condition
New
Name
Evapco Evaporative Cooling Tower Air Inlet Louver
Color
Carbon Black, Grey, etc
Dimension
Length/Width Random, Height 85mm
Sheet Height
25mm
Sheet Thickness
0.25-0.38mm
Usage
Air Inventilation in Evapco Cooling Tower
Materials
PVC
Warranty Period
12 Months
Transport Package
Wooden Pallet, Wooden Crate
Specification
length/width random, width 85mm
Origin
China
HS Code
3926909090
Production Capacity
1000000PCS/Year

Product Description

Product Description

Height 85mm PVC Water and Sight Tight Evapco Cooling Tower WST Air Inlet Louver Modlue Replacement

Evapco air inlet louvers improve air flow into the cooling tower, prevent debris from entering, eliminate water splash-out (which can cause icing,
near-site water damage, and costly water and water treatment chemical loss), restrict the amount of sunlight into the cooling tower (to impede algae growth), reduce noise from the tower, and improve the tower's appearance.


Air Inlet Louvers prohibits the light of the sun from entering the cooling tower basin. Installing air inlet louvers helps control the growth of algae. Controlling the light and limiting algae growth means lowering chemical costs. Air Inlet Louvers also help lower the amount of splash-out from the cooling tower. This reduces the amount of water and chemical needed to run the cooling tower efficiently. Also, you will experience easier basin access and removal. Without proper care and maintenance the air inlet louvers in cooling towers with counterflow can sometimes become scaled. If this happens it reduces cooling tower efficiency.


Louvers that are scaled lessen the air flow to the unit thus lessening the efficiency.
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement

name
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower WST Air Inlet Louver Modlue Replacement
material
new pure PVC
length/width
random
height
85mm
flute height
25mm
sheet thickness
0.3mm-0.6mm
usage
air ventilation in cooling tower
applicable temperature
65°C~-35°C
Product Parameters

Evapco Inlet Air louvers applications
Inlet Louvers replace conventional cement asbestos and fiberglass blade-type inlet louvers in a wide variety of new and retrofit applications, including air inlets for both package and field-erected counterflow and straight-sided crossflow towers, fresh air make-up systems, air pollution control scrubbers, and VOC strippers.

Air louvers Features and Benefits
• Constructed entirely of CTI Standard 136 PVC, for its durability, weather-resistance, and self-extinguishing fire
characteristics
• Promotes algae growth on the interior surfaces of the cooling tower system. This reduces the cost of algae-removal chemicals and labor and allows the tower to operate more efficiently.
• reduces noise leaving the tower through the louver modules by ≈3 decibels.
• Proprietary, engineered cellular baffling restricts splash-out, light, weather, and noise but still achieves very low pressure
drop results.
• Convenient, pre-assembled modules are random dimension
• To make installation easier and to allow easy access for cleaning and maintenance

Detailed Photos

Detailed pictures for Height 85mm PVC Water and Sight Tight Evapco Cooling Tower WST Air Inlet Louver Modlue Replacement
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement

Framed assembly air inlet louver pictures:

Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement


Cellular air inlet Louvers Material
Cellular intake Louvers are constructed of UV-stabliized PVC. This compound has outstanding resistance to weather exposure and is nearly impervious to chemical degradation by alkali, acids, greases, fats, oils, and biological attack. It also has an excellent fire rating due to its self-extinguishing characteristics, and meets or exceeds Cooling Tower Institute Standard 136.


Features of Height 85mm PVC Water and Sight Tight Evapco Cooling Tower WST Air Inlet Louver Modlue Replacement
*Eliminates Sunlight
In addition to eliminating splash-out, air inlet louvers are sight tight. They inhibit algae growth more effectively than previous designs.
*Superior Thermal Performance
Developed with Computational Fluid Dynamics software, louver design has been proven through laboratory tests to maximize airflow while preventing water droplets from leaving the unit, even when the fan motor is de-energized.
*Easy Cold Water Basin Access
Air louver design has no loose hardware and includes framed louver sections that allow for easy removal, handling, and the most accessible basin in the industry.
*Zero-Hardware Louver Design
The newest induced draft equipment features zerohardware louver design.
*Optimum Design Features
The framed PVC louver sections are corrosion resistant, and the new frame design will accept replacement PVC
louver material to minimize replacement part costs. In addition, the pan section incorporates an intermediate louver stop that eliminates splash-out between louver frame sections.
*Upgrade Existing Equipment
Retrofit kits are available for many of your existing tower induced draft units.
 

Product Weights & Dimensions of air intake louvers

SHEET
 
THICKNESS
SHEET
 
SPACING
DRY
 
WEIGHT
MODULE DIMENSIONS
DEPTH
LENGTH
WIDTH
.015 in
 
(.38 mm)
1 in 
 
(25.4 mm)
.95 lbs/ft2
 
(4.6 kg/m2)
85mm
random
random

 

Packaging & Shipping

Package of Height 85mm PVC Water and Sight Tight Evapco Cooling Tower WST Air Inlet Louver Modlue Replacement

wooden crate, wooden pallet or as your request.
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement

 

Installation Instructions

Application of Height 85mm PVC Water and Sight Tight Evapco Cooling Tower WST Air Inlet Louver Modlue Replacement

Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
Related products

Other various cooling tower spare parts:

cooling tower pvc fill materials:
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
cooling tower nozzles:
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
cooling tower drift eliminators:
Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
Company Profile

 

Height 85mm PVC Water and Sight Tight Evapco Cooling Tower Wst Air Inlet Louver Modlue Replacement
FAQ

1.Q: Are you Trading Company or Factory:

   A:.  We are Trading Company and also Factory

 2.Q: What's your production ability for one month?

     A:We can product Metric Tons per Month 200000 pcs  .

 3.Q:  What's your MOQ?

     A:100pcs

 4.Q:What's your shipping port?

    A:Tianjin,shanghai or any port as your reqirement 

 5.Q: What's your Payment Terms?

    A:L/C,T/T,Western Union  

Try order is acceptable. Sample is available.

Welcome to inquire, we will feedback within  24 hours.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Trading Company
Registered Capital
3000000 RMB
Plant Area
101~500 square meters